easier. Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Hi Ray, NOW you may have a bad capacitor. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. Got pump from a friend and he had no problems. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. men's rhinestone dress shoes. Is there something on the board I need to change? If a LED is flashing, wait 60 seconds after starting the filter pump. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). it runs about 30 minutes and trips the breaker. Which explains the clicking of the pump. It can continue to run at that point but its almost like its running at 25% power or even less so we just turned it off. 12 ga or 14 ga? 3. No need to look for a solution after the impeller, its always before, on the suction side. Hi Ric, is the SF service factor rating the same on both motors (new and old)? Then it wouldnt turn back on. Replace with exact duplicated MFD numbers. The stickers and labels mean it is WIRED to allow for 230. Hi Liane, a click coming from a control panel, could be a relay, clicking to send the signal to start the pump, but the signal is lost along the way. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Otherwise it runs all the time or if you try to turn it on/off daily, but youre bound to be unavailable or maybe forget from time to time, I have a super pump and a salt water pool. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. Hi there, I made the very unfortunate decision to rent my home to a friend. I get home from work and the pump is running. I have a Hayward C900 Filter. Sometimes pump lids can also warp or even the pump housing or internals, in cases where the pump got REALLY hot, but that is rare, but if the cause, youd need some new parts, or new pump. Normally they last longer. Currently it is at pool level. It trips 20amp breaker after running 5 or 10 second. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. The air may be there on high speed too, its just not noticeable. We have a circuit board that controls these two motors as well as an LED light.
hayward blue essence troubleshooting - Chhotisunehri.in Hi Davy, I have a Hayward Super II which has been running well for years. But the moment the basket fills with water its like the pump just kicks down to barely running or humming at all. Ray1davis@comcast .net. If any of these readings are outside limits, replace motor. Checked circuit breakers inside and out and checked to make sure power is getting to pump. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. The display shows nothing as if it is not getting power. I have a thermal switch on it,thank goodness or the motor would probably be fried. Do you have the correct cell size chosen in your diagnostics menu? The outlet the pump is plugged into, I suppose that is a 240V outlet. Good morning. Thanks for the schema!! Do you know what would cause this? This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. I have a hayward sp2610x15 1.5hp pump that I got in May 2017. Clean Gasket (no bits of debris or de powder), 2. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. The Super Pump comes with all these labels that say it is set up and wired for 230. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. I backwashed and started again and it was good for another 24 hours and the circulation stopped again and the pressure reached max. I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. Hi Joe, make sure that the pump shaft is spinning freely. View Details Usfitnessfinder.com. Or backwash extra long, 4-5 minutes. Its a 16-14 250 amp connection. Drive Error is a major fault. You can also turn off the pump at the breaker which provides power to the timer. Might be some voltage issues? While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. It just started leaking at the top plumbing connection. Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Guess it is time for a new drive. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. When I try to turn the pump back on, it only hums. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. So we cannot manually rotate the shaft a full revolution. Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. },
Check for water under the display, or in the control box area. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. The pump was working well since opening the pool in May, but the last few days it was quite weak. The main filters and baskets are well maintained. Any ideas? Any ideas on how to fix this issue?? I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. A spike below 100V or above 140V, could blow a capacitor. But, that may not be it, if you say the shaft is getting stuck each time? Could vibration over time wear the pump housing? Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. Could this be my problem? Then hold the shaft stationary to remove the impeller, and finally remove the housing. "width": "611",
The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Sometimes this can be cleared or removed, without pulling the pump apart, which is def. Its a good piece of troubleshooting. Returns are getting good supply, the gauge on filter is bouncing up and down. There is also a leak somewhere in the system because there is water on the pad. Knowing prime was lost I filled the pool and the filter housing up with water. Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. Hi my spa empties into the pool when the spa is turned on. However this is not correct operation. Hi again, I dont have a shaft seal replacement video, but there are many on youtube. K-1766 Taylor Salt Test Hose them off well, and then soak them in a DE filter cleaner, in a 5 gallon bucket. Thanks. that is correct, those are the usual suspects. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. It would run fine. If that doesnt solve the problem, then work through the steps below. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. Step 1: With your pump running, double-check the positions of your valves. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Armstrong Human Resource Management 13th Edition Pdf, Hi Jamie, definitely want to use 100 lbs of Pool Filter Sand, unless you are using a sand replacement like Zeosand or FilterGlass. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? The motor runs but does not Whats the problem. Your pump should be connected to a bare copper wire, test it to see if there is any voltage detected in the bonding wire. My pressure is normal , no water being sucked in from basket and a MINOR trickle coming back out into the pool. I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. Any suggestions? The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. We were cleaning our pool filter one day and went to restart the pump and it didnt. It looks old and Im thinking about replacing it. Step 3: Double check the wires on the flow switch for damage. Round about 1990 the original AG pump and filter were replaced with used Hayward IG equipment. Hi Davy,I have a Hayward pump and its not priming.The basket is only filling up halfway with water. The pump acts like it wants to pump, but doesnt. Whats that part called in case I do break it? Pump shutoff during 24 hours of pouring rain. Had the filter for 3 years. Dont know how to fix this. JUst installed new heyward pump . Loose connections or insect infestation on contacts, or loose breaker etc, could also cause a different type of start/stop problem, very rapid. Shaft seal went out twice and I have a groove in the motor shaft now. Ive never owned a pool before and didnt have any problems all summer until the last 2 weeks. I have a Hayward pool pump/filter, model SP3220EE. And water around the base. The temperature of the pool water is too high or too low to operate.
hayward blue essence troubleshooting - Habikalli.com Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. On the return side, after the heater, the return valve should also move, with Spa Jets fully open and pool returns fully closed. "primaryImageOfPage": {
This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. Contains 13 high-performance titanium electrode plates that are coated with a special formula that combines the most corrosion-resistant metal on earth, iridium and ruthenium, to ensure extended cell life and increased chlorine production efficiency. Maybe the transformer is not functioning properly? Jake, sounds like you got the filter up to speed. Suggestions on what to do next. FYI I moved the voltage selector to 115. Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. For a better experience, please enable JavaScript in your browser before proceeding. At a total loss here, any suggestions would be greatly appreciated. First, I want to ensure the pool is voltage free, thus grounded and all components are bonded, I know many pumps have a zinc plate that actually bonds the water. Or a stuck skimmer weir. See below for more detail.
March 2023 Issue - Donovan's Bookshelf Hi Paul, could it be vibration noise? If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Hi John, do you mean the filter top pops off? I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. Troubleshooting a Salt Chlorinator First, check power. Can I turn on this pump without water to check whether the motor is running? We opened the pool this spring and the pressure rises after 15 to 20 minutes. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
Hello, I have a H200 natural gas heater . Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. The board wasnt showing anything. Troubleshooting Guides; Troubleshooting Guides. Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. Cheers! Thanks. please update your current version of Internet Explorer or try using a different browser. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping Could it have shut it self off from overheating? Thank you so much for taking time to answer all our concerns. My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. 1. You could also adjust the pressure switch (on most heaters), to allow it to come on with slightly less pressure, (1 psi instead of 2 psi). . Have had it for 4-5 years and have had no issues. "url": "https://intheswim.com/",
Help. I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex).